Model
|
RS-232
|
Alfa Digital
|
7310CH |
|
|
Capacity
|
|
1000VA/500W |
|
|
|
Input
|
Voltage |
220/230/240VAC |
| Voltage Range |
172VAC ~288VAC (+/-25%) |
| Frequency |
50Hz |
|
Output
|
Voltage Regulation
(Batt. Mode) |
220/230/240VAC +/-10% |
| Frequency |
50Hz +/-1Hz |
| Waveform |
Simulated Sinewave |
| Transfer Time |
< 6ms (Typical) |
IEC-320:Battery/
Surge only |
4/2 |
|
NEMA 5-15R:Battery/
Surge only |
4/2 |
|
Battery
|
Battery Type |
12V *9Ah |
|
|
| Recharge Time |
5Hrs to 90% after complete discharge |
| User's Replacement |
Yes |
| Battery Protection |
Over discharge protection & Short circuit protection by fuse |
| Advanced Battery Management |
Yes |
Battery Back-up
Time |
30mins (Load
with 1 PC)
|
|
|
|
Function
|
Display |
LED status indicators for AC normal (Green),Back-up(Yellow), UPS cut off (Red) |
| Alarm |
Buzzer on for Back-up mode,Battery low |
Output Short
Protection |
AC fuse and Electronic circuit(Line mode);Electronic circuit (Back-up mode) |
| Communication Port |
Shutdown software for Windows 95/98/NT/2000/ME/XP/Vista |
Modem/Phone
Protection |
RJ-11 |
| Lightning/Surge Protection |
240joules |
| AVR (Auto. Voltage Regulation) |
Boost/Buck |
|
Environment
|
Safety Standard |
CE (EN50091-1,EN62040-1-1) |
| EMC Standard |
FCC Part 15 Class B,CE (EN50091-2,EN55011,EN61000-3-2,EN61000-3-3) |
| Operating Temperature |
0 ~ 40 °C |
| Relative Humidity |
0 ~ 95%, non-condensing |
| Audible Noise |
< 40dB at 1M |
|
Physical
|
Dimension(D*W*H) |
310*95*170mm |
| Net Weight |
7.5Kgs
|
|
|
Ni-MH/Ni-Cd
Battery Charger |
Battery Type |
Rechargeable batteries 'AA' or 'AAA'
(Optional) |
| Charging Channels |
1~4pcs ' A' or ' AAA' |
| Output Charging Voltage |
DC 1.5V |
| Charging Current |
1000mA for 1pc; 500mA for 2pcs; 250mA for 4pcs (' A' or ' AAA' ) |
|
Design,Manufacture,Services
|
ISO 9001-2000 |
|
Warranty
|