Features:
Microprocessor control guarantees high reliability.
Extended back up time with external battery bank.
Unite input power factor and wide input range.
True sinewave double conversion On-Line UPS.
DC start and automatic self-diagnostic function.
RS-232 communication port and built-in SNMP slot.
High efficiency design to save electricity.
Low heat dissipation in long time operation.
Designed to operate under harsh environment.
Enhanced protections against lighting surges, disturbances, etc.
| |
Alfa~9303/L SPECIFICATIONS
|
MODEL
|
LED Display
|
9301 |
9302 |
9303 |
|
LCD Display
|
9301L |
9302L |
9303L |
|
Capacity
|
VA / Watts
|
1KVA / 700W |
2KVA / 1400W |
3KVA / 2100W |
|
Input
|
Voltage Range
|
110V system
|
80V~143V (100% load), 65V~80V (70% load) |
|
220V system
|
160V~286V (100% load), 130V~160V (70% load) |
|
Frequency
|
50Hz / 60Hz (auto sensing) |
|
Power Factor
|
>0.95 |
|
Output
|
Voltage Range
|
110V system
|
110Vac, 115Vac, 120Vac |
|
220V system
|
220Vac, 230Vac, 240Vac |
|
Voltage Regulation
|
±2% |
|
Frequency
|
Synchronized (Line mode), 50Hz or 60Hz ±0.5% (Battery mode) |
|
Wave-form
|
True sine-wave |
|
Distortion
|
<3% (linear load) |
<4% (Full linear load) |
|
Capacity
|
108% ~ 150% for 1 min., >150% for 200ms |
|
Crest Ratio
|
3 : 1 |
|
Efficiency
|
To AC mode
|
85% |
83% |
86% |
|
To Battery mode
|
83% |
82% |
83% |
|
Battery
|
Type
|
Maintenance free sealed lead-acid battery |
|
Voltage
|
36V |
96V |
|
Back-up
(Full / Half load)
|
>5min / 18min
|
>9min / 18min
|
>5min / 15min
|
|
Charging Current (MAX.)
|
1.0A |
|
Recharge Time
|
5hrs to 90% of full capacity after full load discharge |
|
Bypass
|
Automatic
|
Overload and UPS failure |
|
Transfer Time
|
0 ms (2.5ms inverter to bypass) |
|
Display
|
LED
|
Normal (Green), Bypass (Yellow), Inverter (Green), Load% (5 LED), Battery% (5 LED), Fault (Red) |
|
LCD
|
UPS status, I/P & O/P Voltage & Frequency, Load %, Battery voltage & % Model Spec. |
|
Audible Alarm
|
Battery Mode
|
Beeping every 4 seconds (re-settable) and per second when battery low |
|
Overload
|
Beeping twice every second |
|
Fault
|
Beeping Continuously |
|
Communications
|
RS-232 Interface
|
UPSilon-2000 monitoring software |
|
SNMP Intelligent Slot
|
For Net Agent II (Option) with SNMP manager and Web browser |
|
Network
|
Surge Protection
|
RJ-45 I/O port available for 10 base-T network of Fax/Modem |
|
Environment
|
Temperature
|
0°C ~ 40°C (32°F ~ 104°F) |
|
Humidity
|
0-95% non-condensing |
|
Acoustic Noise
|
Less than 45dBA
(at 1 meter)
|
Less than 50dBA
(at 1 meter)
|
|
Safety Standard
|
CE (EN62040-1-1, IEC60950-1) |
|
EMC Standard
|
CE (EN50091-2) |
|
Physical
|
Dimension, W*H*D
|
408*143*205 mm |
460*192*340 mm |
|
Net Weight
|
13kgs |
32kgs |
33kgs |
|
Design, Manufacture, Services
|